API Plan 23/62 | Eng-Tips
Apr 16, 2019 · Can you provide a schematic of "API plan 23/62 + cooling plan M"? Good luck, Latexman To a ChE, the glass is always full - 1/2 air and 1/2 water.
api plan 23 seal piping | Eng-Tips
Feb 5, 2013 · @flexibox this is a plan 23 + 52 arrangement.O-ring material is perfluoroelastomer.@bk19702 cooler is vertically mounted.@ flexibox i am now requesting the …
API PLAN 23 - Cooler configuration | Eng-Tips
Oct 12, 2011 · Hi, For API plan 23 in boiler feed water application or any application in general. Is is better to have the cooler orientation horizontal or vertical. Is there a preference for one over …
API Plan 23 | Eng-Tips
May 4, 2006 · Here are two contradicting views on the clearances for the throat bushing in a API plan 23 environment overhung pump. One view is the throat bushing must be installed at the …
API Plan 23 Cooling Water Requirements | Eng-Tips
Jan 25, 2018 · API 682 doesn't spec parameters like flow rate, pressure, or temperature but it does give general guidelines. For instance, Plan 23 is generally the plan of choice for boiler …
API Plan 23 Seal Flush Tubing Material for Water with Chlorides
Aug 14, 2012 · What piping or tubing material is best suited for water with small amounts of HCl and chlorides? I have an API plan 23 and the specified material is Stainless Steel tubing but I …
When to select Seal Plan 21 over Plan 23? | Eng-Tips
Aug 27, 2014 · Dear All, As per API 682, if the temperature is more than 80 deg. c, we should select seal plan 23 (more efficient seal plan with less heat load)? But in many applications, i …
API Flush Plan for HSRN and RCO | Eng-Tips
Sep 11, 2011 · In one of the jobs I have to specify a pump which will operate on 02 services. One service is HSRN (Heavy Straight Run Naphtha) and the second service is RCO (Reduced …
API flush plan difference between seal flush and external flush
May 10, 2011 · You need to get a copy of API 682 for future reference and you may want to contact your local seal supplier who can give you a Piping Plan Booklet (Pocket Size) Plan 11 …
API PLAN 23 Heat Exchanger | Eng-Tips
Sep 6, 2010 · We are purchasing a BFW pump, and the pump vendor has proposed TEMA C Cooler for API PLAN 23. Is this usual for pump sealing systems? What are the requirements of …