Installing a Tigerloop - Screwfix Community Forum
Mar 14, 2010 · Looking for advise. Away to install a tigerloop system into my oil heating pipework but been told by various people to have it outside, some say inside,other say high up the wall and other …
Tigerloop venting - Screwfix Community Forum
Dec 9, 2024 · I have an oil fired boiler in the garage, with a Tigerloop. This is the original Tigerloop installed in the late 90's (yes is still the original and working well, so suspect they were built better …
Tiger Loop / oil feed problem | Screwfix Community Forum
Apr 19, 2012 · Hello all, I have a problem with a tiger loop, it may not be the tiger loop itself, but problem is as follows. New WB boiler with Riello burner. Tank level is not that far below burner level but as …
Is there a problem with my tiger loop. - Screwfix Community Forum
Jan 24, 2021 · My question is has my tiger loop failed.the TigerLoop I have is an Original type T110 I know people on the forum have issues with not using registered plumbers. And I can understand …
Where to Put Tiger Loop de-airator - Screwfix Community Forum
Sep 25, 2023 · Fire valve needs to be 1 m of pipework away, tigerloop should not be installed inside case, isolator is on tank and normally included inside appliances. All deaerator should now be of …
Foam in Tigerloop - split in oil pickup in tank / should it float
Jan 22, 2017 · I've been having issues with bubbles / foam and low level of oil in my tigerloop, and boiler cutting out. After a bit of faffing, and ruling out boiler issues or oil lift pump issues (I hope), I've come …
Tiger Loop Leak - Screwfix Community Forum
Sep 15, 2018 · Replace it. They only have a limited life and are not repairable as I understand. Should really be an internal Tigerloop with vent pipe to outside for current regs. Expensive though. The …
tigerloop - Screwfix Community Forum
Foam in Tigerloop - split in oil pickup in tank / should it float ? I've been having issues with bubbles / foam and low level of oil in my tigerloop, and boiler cutting out. After a bit of faffing, and ruling out …
RCD keeps tripping in rainy weather since having PV system installed
Apr 12, 2023 · We have had no history of our RCD tripping until solar panels were fitted last month. Since then our RCD frequently trips when it rains. The technician who fitted the PV system told me it …
Oil Boiler Bleed - Screwfix Community Forum
Jan 22, 2020 · Pressing the lockout button won’t prime the it unless there is an aerator Tigerloop type device connected to boiler. The oil pipe run and oil pump in burner will be full of air.